Siemens Flags Mendix Runtime Flaw That Lets Deactivated Users Keep Active Sessions
According to Siemens ProductCERT, advisory SSA-579716 covers CVE-2026-135278, a flaw in Mendix Runtime that can let a deactivated account keep using an already open session. Fixed builds are listed for several release lines.
ICS / OTVulnerabilitiesKey points
- Siemens ProductCERT's advisory SSA-579716 covers CVE-2026-135278 in Mendix Runtime.
- Deactivated users can keep using sessions opened before deactivation, because account status is checked only at sign-in.
- Fixed versions are listed for the V9, V10, V11, V11.6 and V11.12 lines.
- The report does not state whether exploitation in the wild has been observed.
According to Siemens ProductCERT, advisory SSA-579716 (version 1.0, published 27 November 2026) describes a flaw in Mendix Runtime. A user whose account has been deactivated can keep using a session that was already open, and can read and modify data within the permissions previously granted. The advisory assigns the issue CVE-2026-135278.
Cause
Per the advisory, the runtime checks account status only at sign-in, not on later requests made under an existing session. An account deactivated mid-session therefore keeps its access. The advisory says an authenticated remote attacker could exploit this to reach data within previously granted permissions for a persistent session.
Affected versions and fixes
Siemens lists the following builds as affected, with fixes in the stated version or later:
- Mendix Runtime V9: builds before V9.24.45, fixed in V9.24.45
- Mendix Runtime V10: builds before V10.24.29, fixed in V10.24.29
- Mendix Runtime V11: builds before V11.17.0, fixed in V11.17.0
- Mendix Runtime V11.6: builds before V11.6.13, fixed in V11.6.13
- Mendix Runtime V11.12: builds before V11.12.8, fixed in V11.12.8
Siemens recommends updating to the latest release.
Severity and open questions
The advisory gives a CVSS v3.1 base vector of AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N and a CVSS v4.0 vector of AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N. Both reflect low confidentiality and integrity impact. The report does not state whether the flaw is being exploited in the wild, and it does not mention a public proof of concept. Read the original advisory from Siemens ProductCERT for full details.
What to do
- Identify Mendix Runtime deployments and their version lines, and compare them against the fixed versions in the advisory.
- Update affected runtimes to the listed fixed version or the latest release Siemens recommends.
- Protect network access to affected systems, as Siemens advises.
- Follow Siemens operational guidelines for industrial security.
Original report
“SSA-579716 V1.0: Insufficient Session Expiration Vulnerability in Mendix Runtime”
The products listed below contain a session management vulnerability that could allow a deactivated user to continue using an existing session to access and modify data within their previously granted permissions. Siemens has released new versions for the affected products and recommends to update to the latest versions.