Exploited now
Vulnerability WatchVulnerabilities, exploits & advisories — updated every 15 minutes
Alerts

Home › CVE › Ivanti

CVE-2026-118527 — Ivanti Connect Secure Generation of Predictable Numbers or Identifiers Vulnerability

Actively exploited (CISA KEV)Medium · CVSS 4.3EPSS 0.8% First seen November 03, 2026
IvantiNetwork devicesVulnerabilities

Research article

Ivanti Connect Secure CVE-2026-118527: predictable identifiers let authenticated users plant files, exploited in the wild

CVECVE-2026-118527
Vendor and productIvanti Connect Secure
PublishedNovember 12, 2026 10:50 UTC
Research cut-offNovember 12, 2026 10:45 UTC
Sources reviewed3: NVD record (last modified 2026-11-03); CISA KEV catalog; 1 vendor bulletin

Executive summary

CVE-2026-118527 is a flaw in Ivanti Connect Secure that is classified as CWE-340 (Generation of Predictable Numbers or Identifiers) [1]. According to CISA, it lets a remote attacker who already holds valid credentials write files with content they choose to a disk location they can predict [2]. The NVD record carries one secondary CVSS 3.1 score of 4.3 (Medium), vector CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N [1]. NVD lists Connect Secure 25.1.0.0 up to but not including 25.1.1.3 (fixed in 25.1.1.3) and 22.8 r2 through 22.8 r2.5 as affected [1]. The reviewed sources give no fixed release for the 22.8 r2 branch. CISA added the CVE to its Known Exploited Vulnerabilities (KEV) catalog on 2026-10-30, confirming exploitation in the wild, and notes it can be chained with CVE-2026-104935 and CVE-2026-111357 [2]. That chaining means the Medium score understates the practical risk. Defenders should immediately identify every Connect Secure appliance, move 25.1.x systems to 25.1.1.3 or later, and apply Ivanti's instructions for the linked advisory. They should also run a compromise assessment on any appliance that was internet-exposed while vulnerable; US federal agencies face a KEV due date of 2026-11-13 [1, 2].

Key points

  • Ivanti Connect Secure flaw CWE-340 lets an authenticated remote user place attacker-controlled files at a predictable disk location [1, 2].
  • CVSS 3.1 is 4.3 Medium (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N), but CISA confirms exploitation in the wild and chaining with CVE-2026-104935 and CVE-2026-111357 [1, 2].
  • NVD lists 25.1.0.0 up to but not including 25.1.1.3 as affected (fixed in 25.1.1.3), plus 22.8 r2 through 22.8 r2.5, for which no fix is given [1].
  • CISA added the CVE to KEV on 2026-10-30, with a federal due date of 2026-11-13 [2].
  • No indicators of compromise or public proof of concept appear in the reviewed sources.

Vulnerability identification

FieldValue
CVE IDCVE-2026-118527 [1]
VendorIvanti [1, 2]
ProductConnect Secure (ICS) [1, 2]
ComponentNot established by the reviewed sources. CISA describes a file-upload capability that reachable authenticated users can use [2].
Affected platformIvanti Connect Secure appliance software, as listed in NVD CPE configurations [1]
Published (NVD)2026-11-03T15:17:24 [1]
Last modified (NVD)2026-11-03T17:48:12 [1]
Record statusAnalyzed [1]
CWECWE-340, Generation of Predictable Numbers or Identifiers [1]
CVSS 3.14.3 MEDIUM, CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N, scored by 3c1d8aa1-5a33-4ea4-8992-aadd6440af75 (Secondary) [1]
CISA KEVListed; added 2026-10-30; federal due date 2026-11-13 [2]
Related CVEsCVE-2026-104935 and CVE-2026-111357, which CISA says can be chained with this CVE [2]
Vendor advisoryIvanti advisory titled for CVE-2026-104935, referenced by both NVD and CISA [1, 2]
Other bulletinsCERT-In CIVN-2026-0547. The provided text does not mention this CVE by ID [3].

About the weakness. CWE-340 covers software that produces identifiers an attacker can guess or derive [1]. Examples include file names, tokens, session or object IDs and temporary paths. Such values are often treated as secrets or as unguessable. When they are predictable, controls that depend on them being unknown stop working.

Discrepancies and caveats.

  • Only one CVSS score is present, and it is marked Secondary. The pack does not identify the scoring organization behind the UUID [1].
  • CISA listed the CVE in KEV on 2026-10-30, four days before the NVD publication date of 2026-11-03 [1, 2].
  • The vendor advisory referenced for this CVE is titled for CVE-2026-104935. The contents of that advisory are not in the evidence pack [1, 2].

Technical background

Ivanti Connect Secure is a remote-access gateway product [1, 2]. Organizations typically place such an appliance at the network edge so that remote users can authenticate and reach internal resources (Analyst assessment). That placement makes it a trust boundary between the internet and the internal network.

Terms used in this article:

  • Authenticated attacker: someone holding valid credentials or a valid session on the appliance. CISA's description and the CVSS PR:L metric both indicate that this vulnerability requires such access [1, 2].
  • Predictable identifier: a name or value the software generates that an attacker can anticipate.
  • Exploit chain: a sequence in which several vulnerabilities are combined to reach an outcome none would achieve alone.

The sources do not describe which Connect Secure subsystem accepts the uploaded files, or how it names and stores them. Not established by the reviewed sources.

Vulnerability description

  • What it allows (Confirmed by CISA): a remote attacker who is authenticated can upload files with chosen content to a location on disk that is known in advance [2].
  • Security property violated: integrity. The CVSS vector rates integrity impact Low and confidentiality and availability impact None [1].
  • Weakness: the predictability of generated numbers or identifiers (CWE-340) [1]. Analyst assessment: the predictable value is most likely the file name or path assigned to uploaded content. That would explain why the storage location is known to the attacker.
  • Conditions: network reachability of the appliance and valid low-privilege authentication [1, 2].
  • Chaining: CISA states the flaw can be chained with CVE-2026-104935 and CVE-2026-111357 [2]. The pack does not describe those two CVEs or the outcome of the chain.

What the evidence does not establish:

  • That this CVE alone gives code execution, data disclosure or unauthenticated access.
  • Which file types or paths are involved.

Analyst assessment: placing attacker-controlled content at a known path is a common building block for later steps in a chain. That likely explains why a Medium-scored issue is being exploited.

Root cause analysis

  • Confirmed: the flaw is classified as generation of predictable numbers or identifiers (CWE-340) [1]. The consequence is a file written to a predictable on-disk location [2].
  • Not disclosed: the specific coding error, the affected function and the naming algorithm are not in the reviewed sources. The vendor advisory contents are not in the pack.
  • Analyst assessment: typical causes of this weakness class include:
  • deriving file names from timestamps, counters or user-supplied values instead of a cryptographically secure random source;
  • storing uploads at a fixed or guessable path without restricting where they can later be referenced.
  • Analyst assessment on why controls fail: authentication alone does not prevent misuse here. Any low-privilege user, or anyone holding stolen credentials, passes that check [1, 2].

Technical mechanics

The flow below is Illustrative. It is based only on CISA's description and the CWE classification, not on vendor technical detail [1, 2].

  1. The attacker reaches the Connect Secure appliance over the network (AV:N) [1].
  2. The attacker authenticates with a low-privileged account (PR:L) [1].
  3. The attacker submits a file whose content they control through an upload capability [2].
  4. The appliance stores the file under an identifier or path the attacker can predict (CWE-340) [1, 2].
  5. Because the location is known, a further flaw can reference or act on the planted file. CISA cites CVE-2026-104935 and CVE-2026-111357 as chainable [2]. How they interact is not established by the reviewed sources.

The missing control is unpredictable, server-assigned storage identifiers. This should be combined with storage isolation that prevents uploaded content from being referenced by other components (Analyst assessment).

Illustrative
[Remote user w/ valid creds] --HTTPS?--> [ICS upload function]
        |                                   |
        |                       stores file at predictable path (CWE-340)
        v                                   v
[Second flaw in chain] ----references----> [attacker-controlled file]
(CVE-2026-104935 / CVE-2026-111357 per CISA; mechanism unknown)

The protocol and port are not stated in the sources. The "HTTPS?" label in the diagram is an assumption.

Attack surface and exploitation prerequisites

PrerequisiteStatusSource
Access vectorNetwork; the attacker is described as remote[1, 2]
AuthenticationRequired, low privilege[1, 2]
User interactionNone (UI:N); known only from the CVSS vector[1]
Attack complexityLow (AC:L); known only from the CVSS vector[1]
Required feature or configurationNot established by the reviewed sources-
Reachable interfaceNot established; analyst assumption is the user-facing web portal-
Credential sourceNot established. Analyst assessment: stolen or phished VPN credentials, or an authentication bypass from another CVE, could satisfy this requirement. Whether CVE-2026-104935 or CVE-2026-111357 provides that bypass is unknown.[2]

Exploitation scenarios and attack lifecycle

Scenario 1: documented chain (partially Confirmed). CISA confirms that the CVE is exploited and can be chained with CVE-2026-104935 and CVE-2026-111357 [2]. The order of the steps and the final outcome are not documented in the pack.

Scenario 2: credentialed foothold (Illustrative).

  1. An attacker who holds a compromised employee VPN account authenticates to an internet-facing appliance.
  2. The attacker uploads a crafted file to a predictable location.
  3. The attacker then triggers a second flaw that consumes that file.

Defensive opportunities at each stage:

  • Multi-factor authentication and anomaly detection on VPN logins.
  • Logging of file-upload activity by user accounts.
  • Patching to 25.1.1.3 to remove this link in the chain [1].
  • Network segmentation behind the appliance to limit post-exploitation reach.

Impact analysis

AreaDemonstrated / scoredPlausible downstream (Analyst assessment)
ConfidentialityNone, per CVSS [1]Possible through the chain; not established
IntegrityLow: attacker-controlled files written to disk [1, 2]Tampering with appliance state if a chained flaw consumes the file
AvailabilityNone, per CVSS [1]Not established
Authentication / authorizationRequires valid authentication [2]The gateway's trust boundary is weakened if the chain escalates
Privilege boundariesScope unchanged (S:U) [1]Chained outcome unknown
Data and privacyNot establishedA compromised VPN gateway can expose credentials and user sessions
Business operationsNot establishedEmergency patching or temporary shutdown of remote access
RegulatoryUS federal agencies must act under BOD 26-04 [2]Breach-notification duties if compromise is confirmed

Affected products and versions

VendorProductAffectedFixedSource / confidence
IvantiConnect Secure≥ 25.1.0.0, < 25.1.1.325.1.1.3NVD CPE [1]; high confidence for the range, but not cross-checked against vendor advisory text
IvantiConnect Secure22.8 r2, 22.8 r2.1, 22.8 r2.2 through 22.8 r2.5 (six versions)Not established by the reviewed sourcesNVD CPE [1]

Additional notes:

  • The CERT-In bulletin CIVN-2026-0547 is truncated and does not identify this CVE. It cannot confirm or extend these ranges [3].
  • No configuration-specific exclusions are documented.
  • Other Ivanti products are not listed for this CVE in the reviewed sources.

Exploitation and threat intelligence status

EvidenceStatusDateSource
Exploitation in the wildConfirmed (CISA KEV)Added 2026-10-30[2]
Federal remediation deadline2026-11-13-[2]
Ransomware useUnknown-[2]
ChainingWith CVE-2026-104935 and CVE-2026-111357-[2]
Public proof of conceptNot established by the reviewed sources--
Threat actors / sectorsNot established by the reviewed sources--
EPSS scoreNot included in the pack--

The absence of attribution or proof-of-concept references in the pack does not mean that none exist.

Indicators of compromise

The reviewed sources provide no indicators of compromise for this CVE: no hashes, file names, paths, IP addresses, domains or log events. If the Ivanti advisory for CVE-2026-104935 or CISA's forensics triage guidance supplies indicators, obtain them from those documents directly [2]. Validate any indicator before blocking, because indicators go stale.

Detection and exposure assessment

  1. Inventory. List every Ivanti Connect Secure appliance, including lab, disaster-recovery and cloud-hosted instances. Record each appliance's software version from its administrative console.
  2. Version comparison. Compare each version against the NVD ranges [1]:
  • 25.1.x below 25.1.1.3 is affected.
  • 22.8 r2 through 22.8 r2.5 is affected.
  • A version match shows exposure to the flaw, not that the appliance was compromised.
  1. Internet exposure. Determine from firewall rules and external attack-surface scans which appliances are reachable from the internet. CISA requires per-asset evaluation of internet exposure [2].
  2. Authenticated scanning. Run your vulnerability scanner's check for CVE-2026-118527 where one exists. Confirm the plugin detects the 22.8 r2 branch as well as 25.1.x.
  3. Log review. Review appliance user-access and event logs, plus any logs forwarded to the SIEM, for:
  • authentications from unusual geographies or ASNs;
  • accounts performing file uploads they normally would not.

No specific log signature is provided by the sources.

  1. Chained CVEs. Assess exposure to CVE-2026-104935 and CVE-2026-111357 at the same time, because the risk lies in the chain [2].

No vendor-specific commands are given in the sources, so none are reproduced here.

Immediate mitigation

PriorityActionProtects againstLimitations / side effectsVerifyBasis
1Apply Ivanti's mitigation instructions from the CVE-2026-104935 advisoryExploitation per the vendor's guidanceContents not in the pack; obtain them from IvantiVendor-specified check[1, 2]
2Upgrade 25.1.x to 25.1.1.3 (see Permanent remediation)This CVERequires a maintenance windowConsole version shows ≥ 25.1.1.3[1]
3Restrict the user portal to known IP ranges where business allowsReduces the number of potential attackersMay block legitimate roaming usersExternal scan from a non-allowlisted address failsAnalyst assessment
4Enforce MFA and reset passwords for accounts with suspicious loginsLimits misuse of stolen credentials, which the attack requiresUser frictionAuthentication logs show MFA on all sessionsAnalyst assessment based on PR:L [1]
5Disconnect the appliance if neither mitigation nor patch is possibleAll network exploitationRemote access outageNo listener reachableCISA required action [2]

Permanent remediation

  • 25.1.x branch: upgrade to 25.1.1.3 or later, which NVD lists as the fixed version [1].
  • 22.8 r2 branch (22.8 r2 through 22.8 r2.5): the pack gives no fixed version. Consult Ivanti's advisory and either move to the release it specifies or migrate to a fixed 25.1 release [1].
  • Vendor identifier: the advisory is the Ivanti security advisory for CVE-2026-104935 [1, 2].
  • Operational steps (Analyst assessment):
  • Export the appliance configuration before upgrading.
  • Schedule a maintenance window and confirm a rollback image exists.
  • Verify that the clustered or standby node is upgraded as well.

Restart requirements and post-upgrade configuration changes are not documented in the pack. Because exploitation is confirmed, upgrading does not remove anything an attacker already planted. Perform a compromise assessment in addition to patching, in line with CISA's forensics triage requirement [2].

Workarounds and compensating controls

No vendor workaround is described in the reviewed sources. CISA's required action allows vendor mitigations, or discontinuing use where mitigations are unavailable [2].

Compensating controls (Analyst assessment):

  • allowlisting source IP addresses;
  • MFA;
  • reduced account privileges;
  • heightened log review.

These controls shrink the pool of attackers but leave the predictable-identifier flaw in place. An attacker holding valid credentials from an allowed network can still exploit it. They do not replace the upgrade.

Validation and verification

CheckMethodEvidence to record
Installed versionAdministrative console shows 25.1.1.3 or later, or the vendor-specified fixed 22.8 build [1]Screenshot or export, date, owner
All nodesEach cluster member and standby node checkedNode list
Vendor mitigationSteps from the Ivanti advisory confirmed as applied [1, 2]Change ticket
ScannerRe-run the authenticated scan for CVE-2026-118527 and the chained CVEsScan report
Service healthUsers can authenticate and reach resources; no errors after the upgradeMonitoring dashboards
Compensating controlsIP allowlists and MFA still enforced where retainedConfiguration export
Compromise assessmentForensic triage completed for appliances exposed while vulnerable [2]Report, exceptions

A single clean check does not prove the appliance is secure.

Incident response

  1. Triage. Treat any affected, internet-exposed appliance as potentially compromised, given the confirmed exploitation [2].
  2. Preserve evidence. Capture logs, configuration and any available system snapshot before rebuilding or upgrading. Follow CISA's Forensics Triage Requirements where applicable [2].
  3. Contain. Restrict access to or isolate the appliance. Avoid wiping it before evidence is collected.
  4. Investigate.
  • Review the authentication history of the accounts used.
  • Review internal connections originating from the appliance.
  • Check for unexpected files, using vendor guidance for locations.
  1. Rotate credentials. If compromise is indicated, rotate credentials and secrets that transit or are stored on the gateway: user passwords, service accounts and certificates (Analyst assessment).
  2. Eradicate and recover. Upgrade or rebuild to a fixed version, then monitor closely after recovery.
  3. Report. Meet regulatory and contractual notification duties. Federal agencies follow BOD 26-04 [2].
  4. Lessons learned. Record the time taken to patch versus the KEV due date.

Security hardening and prevention

  • For Ivanti (secure development, Analyst assessment):
  • Generate storage identifiers with a cryptographically secure random source.
  • Keep user uploads outside locations that other components execute or parse.
  • Add regression tests for upload naming.
  • For operators (defence in depth):
  • Do not expose management interfaces to the internet.
  • Require MFA for all VPN users.
  • Forward appliance logs to a SIEM.
  • Track KEV additions for edge devices with a remediation target shorter than the KEV due date.

Risk assessment

  • Technical severity: CVSS 3.1 4.3 Medium [1].
  • Exploitation evidence: confirmed in the wild through KEV [2].
  • Chaining: the flaw is chainable with two other CVEs [2], which raises the practical risk well above the base score.
  • Prerequisites: authentication is required [1, 2]. This is a weak barrier for a VPN gateway, where credentials are a frequent target.
  • Asset criticality (Analyst assessment): high, because the appliance sits at the network edge.
  • Recommended priority: urgent. Remediate within days, before the 2026-11-13 federal due date where possible [2].

This organizational rating assumes an internet-facing appliance with a broad user base. It is not the CVSS score.

Conclusion

CVE-2026-118527 is a predictable-identifier flaw in Ivanti Connect Secure. It lets authenticated users place controlled files at known disk paths and forms part of an exploited chain with CVE-2026-104935 and CVE-2026-111357 [1, 2]. Network and VPN teams operating Connect Secure should act now:

  • Apply Ivanti's advisory instructions.
  • Upgrade 25.1.x to 25.1.1.3 or later [1].
  • Obtain the vendor fix for 22.8 r2 through 22.8 r2.5.
  • Run a forensic triage on exposed appliances [2].

Closing the issue requires four pieces of evidence: the verified version on every node, the applied vendor mitigation, a clean rescan, and a documented compromise assessment.

Remediation checklist

  1. Inventory all Ivanti Connect Secure appliances and nodes, and record each version from the admin console against the NVD ranges: 25.1.x below 25.1.1.3, and 22.8 r2 through 22.8 r2.5 [1].
  2. Apply the mitigation instructions in Ivanti's advisory for CVE-2026-104935, which NVD and CISA reference for this CVE, and record a change ticket for each appliance [1, 2].
  3. Upgrade 25.1.x appliances to 25.1.1.3 or later, including standby and cluster nodes; verify the console reports at least 25.1.1.3 [1].
  4. For 22.8 r2 through 22.8 r2.5, obtain Ivanti's fixed release from the advisory or migrate to a fixed 25.1 release; verify the build afterwards [1].
  5. Before patching or rebuilding any internet-exposed appliance that was vulnerable, preserve logs and configuration and perform forensic triage per CISA's Forensics Triage Requirements [2].
  6. Remediate CVE-2026-104935 and CVE-2026-111357 in the same change window, because CISA documents chaining [2].
  7. Until patched, restrict portal access to known source IP ranges and enforce MFA; confirm with an external scan and the authentication logs (Analyst assessment based on PR:L) [1].
  8. If neither patch nor mitigation can be applied by 2026-11-13, disconnect the appliance, as CISA's required action permits [2].
  9. Re-run an authenticated vulnerability scan after the changes and file the version evidence, scan report, owner and date [1].

Evidence gaps

  • The fixed version for the 22.8 r2 branch is missing from the pack; Ivanti's advisory text would settle it.
  • The technical root cause, affected component, upload function and naming algorithm are not disclosed; vendor technical detail or a researcher write-up would settle them.
  • The content of Ivanti's advisory (titled for CVE-2026-104935) is not in the pack, including mitigation steps and any restart requirements.
  • The nature and order of the chain with CVE-2026-104935 and CVE-2026-111357, and its end impact, are not described.
  • No indicators of compromise, threat actor attribution, targeted sectors or public proof of concept are provided; vendor, CISA or incident-response reporting would settle these.
  • The identity of the secondary CVSS scorer (UUID 3c1d8aa1-5a33-4ea4-8992-aadd6440af75) and whether another score exists are not established.
  • No EPSS score is included in the pack.
  • The CERT-In bulletin CIVN-2026-0547 is truncated and does not identify this CVE, so it cannot corroborate affected versions.

References

  1. CVE-2026-118527 record. NIST National Vulnerability Database (NVD), 2026-11-03. https://nvd.nist.gov/vuln/detail/CVE-2026-118527. Accessed 2026-11-12. Record status, dates, CVSS 3.1 score and vector, CWE-340, CPE affected ranges, 25.1.1.3 fix, and the vendor advisory reference titled for CVE-2026-104935
  2. Known Exploited Vulnerabilities Catalog: CVE-2026-118527. Cybersecurity and Infrastructure Security Agency (CISA), 2026-10-30. https://www.cisa.gov/known-exploited-vulnerabilities-catalog. Accessed 2026-11-12. KEV listing (added 2026-10-30, due 2026-11-13), confirmed exploitation, authenticated file-upload-to-known-location description, chaining with CVE-2026-104935 and CVE-2026-111357, required action under BOD 26-04, forensic triage, unknown ransomware use
  3. Multiple Vulnerabilities in Ivanti Connect Secure (ICS) (CIVN-2026-0547). CERT-In, 2026-11-12. https://www.cert-in.org.in/s2cMainServlet?pageid=PUBVLNOTES01&VLCODE=CIVN-2026-0547. Accessed 2026-11-12. CERT-In CIVN-2026-0547 exists but its truncated text does not tie it to this CVE

Written with AI assistance from the 3 sources listed above, as of the research cut-off; each fact is cited to its source. Check the vendor's advisory before acting.

Summary

Use of predictable filenames in Ivanti Connect Secure before versions 25.1.1.3 and 22.8R2.6 allows a remote authenticated attacker to upload files with attacker-controlled content to a known location on disk.

Description: NIST National Vulnerability Database (public domain)

Severity breakdown

Medium · 4.3 CVSS 3.1 base score from the CNA

An attacker with a normal user account can exploit this over the network, without any user action.

Attack from
the network (remotely)
Attack complexity
low (no special conditions)
Login needed
yes, a normal user account
User action needed
no
Scope
stays within the vulnerable component
Impact
low on integrity, none on confidentiality and availability

Vector CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N

Weakness

  • CWE-340: Generation of Predictable Numbers or Identifiers

Affected and fixed versions

ProductAffected versionsFixed in
ivanti connect secure≥ 25.1.0.0, < 25.1.1.325.1.1.3
22.8 r2, 22.8 r2.1, 22.8 r2.2 … 22.8 r2.5 (6 versions)—

From NVD's CPE data; confirm with the vendor advisory before relying on a version number.

CISA KEV

Exploited in the wild

Ivanti Connect Secure contains a generation of predictable numbers or identifiers vulnerability that allows a remote authenticated attacker to upload files with attacker-controlled content to a known location on disk. This vulnerability can be chained with CVE-2026-104935 and CVE-2026-111357.

Listed as
Ivanti Connect Secure Generation of Predictable Numbers or Identifiers Vulnerability
Added to the catalog
October 30, 2026
Federal due date
November 13, 2026
Required action
Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.
Ransomware use
Not known

US federal agencies must fix catalog entries by the due date; everyone else should treat them as a priority. CISA catalog entry

References by type

Vendor advisories

Details from NVD (public domain), CISA KEV (CC0).

Affected

  • Ivanti Connect Secure

Frequently asked questions

What is CVE-2026-118527?

CVE-2026-118527 is a flaw in Ivanti Connect Secure that is classified as CWE-340 (Generation of Predictable Numbers or Identifiers). According to CISA, it lets a remote attacker who already holds valid credentials write files with content they choose to a disk location they can predict. The NVD record carries one secondary CVSS 3.1 score of 4.3 (Medium), vector CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N. Weakness type: Generation of Predictable Numbers or Identifiers (CWE-340).

How severe is CVE-2026-118527?

CVE-2026-118527 has a CVSS 3.1 base score of 4.3 (medium), from the CNA. An attacker with a normal user account can exploit this over the network, without any user action.

Is CVE-2026-118527 being exploited?

Yes. CISA lists CVE-2026-118527 in its Known Exploited Vulnerabilities (KEV) catalog, added October 30, 2026: it has been exploited in real attacks. US federal agencies must fix it by November 13, 2026.

Which versions are affected by CVE-2026-118527?

ivanti connect secure ≥ 25.1.0.0, < 25.1.1.3 (fixed in 25.1.1.3); ivanti connect secure 22.8 r2, 22.8 r2.1, 22.8 r2.2 … 22.8 r2.5 (6 versions).

How do I fix CVE-2026-118527?

Inventory all Ivanti Connect Secure appliances and nodes, and record each version from the admin console against the NVD ranges: 25.1.x below 25.1.1.3, and 22.8 r2 through 22.8 r2.5. Apply the mitigation instructions in Ivanti's advisory for CVE-2026-104935, which NVD and CISA reference for this CVE, and record a change ticket for each appliance. Upgrade 25.1.x appliances to 25.1.1.3 or later, including standby and cluster nodes; verify the console reports at least 25.1.1.3.

Timeline & sources

References

Related vulnerabilities & news