Exploited now
Vulnerability WatchVulnerabilities, exploits & advisories — updated every 15 minutes
Alerts

Home › CVE › Windows

CVE-2026-114031 — Illumio Core Ven

High · CVSS 7.8EPSS 0.1% First seen November 09, 2026

One of 2 Illumio Core Ven vulnerabilities published together by NVD: our article covers all of them.

WindowsOperating systemsVulnerabilities

Research article

Illumio VEN for Windows: permission assignment error allows local escalation to SYSTEM (CVE-2026-114031)

CVECVE-2026-114031
Vendor and productIllumio Core Ven
PublishedNovember 12, 2026 07:20 UTC
Research cut-offNovember 12, 2026 07:12 UTC
Sources reviewed3: NVD record (last modified 2026-11-10); CISA KEV catalog; FIRST EPSS (2026-11-10)

Executive summary

CVE-2026-114031 is a permission-assignment weakness (CWE-732) in the Windows build of the Illumio VEN, which can let a local account that already runs code as LOCAL SERVICE raise its rights to SYSTEM [1]. The only score in the pack is CVSS 3.1 7.8 HIGH with vector CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H, recorded by the vendor's security address as a Secondary scorer [1]. The vendor's CVE record lists Illumio Core VEN release lines from 23.2.22 through 26.2.12, each with a fixed -S1 release [1]. Exploitation requires an attacker to already execute code as LOCAL SERVICE on the host and to modify configuration that a SYSTEM-context component trusts [1]. As of 2026-11-12 the CVE is not in the CISA KEV catalog, and the reviewed sources report no confirmed in-the-wild exploitation; the FIRST EPSS estimate is 0.0010 for 30-day exploitation activity, which is a statistical estimate and not evidence of exploitation [2, 3]. The most important immediate action is to inventory Windows VEN hosts, compare their versions with the affected table, and upgrade each to the matching -S1 release, while restricting LOCAL SERVICE write access to the VEN directories as an interim measure that the vendor has not confirmed [1].

Key points

  • CVE-2026-114031 is an incorrect permission assignment (CWE-732) in the Windows Illumio VEN that lets a LOCAL SERVICE code-execution foothold reach SYSTEM [1].
  • Vendor-supplied CVSS 3.1 score is 7.8 HIGH with vector CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H [1].
  • The vendor record lists affected Illumio Core VEN release lines from 23.2.22 to 26.2.12, each fixed in its -S1 release [1].
  • Not in CISA KEV as of 2026-11-12, and the reviewed sources report no confirmed exploitation; EPSS is 0.0010 [2, 3].
  • Immediate actions: inventory Windows VEN hosts, restrict LOCAL SERVICE write access to VEN directories after testing, and upgrade to the matching -S1 release [1].

Vulnerability identification

FieldValueSource
CVE IDCVE-2026-114031S1
VendorIllumioS1
Product as listed in the CVE recordIllumio Core VEN (written 'Illumio Core Ven' in the record)S1
PlatformWindows, per the record descriptionS1
ComponentThe VEN installer, and the SYSTEM-context component illumio-ven-ctl that reads the files the installer sets upS1
Published2026-11-09T22:18:27S1
Last modified2026-11-10T20:18:00S1
Record statusReceived. The record does not show completed NVD analysisS1
CWECWE-732, Incorrect Permission Assignment for Critical ResourceS1
CVSS 3.1 base score7.8, HIGHS1
CVSS vectorCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:HS1
Scoring version and scorerCVSS 3.1, scored by security@illumio.com, recorded as SecondaryS1
CISA KEV statusNot listed as of 2026-11-12S2
EPSS0.0010 (0.10%), percentile 0.0092, dated 2026-11-10S3
Related advisoryA vendor security advisory on the Illumio documentation site, whose address refers to insecure folder permissions in the Windows VEN. Its content is not in the packS1
Related CVEsNone listed in the reviewed sourcesS1

The pack contains a single CVSS score, supplied by the vendor's security address. No NVD-assigned score appears because the record is still in the Received state [1]. The CWE mapping is listed in the record; the pack does not contain a separate NVD CWE analysis to compare with it [1].

Technical background

The reviewed sources describe the VEN as Illumio software installed on Windows hosts. The record says that its configuration and state files are read by a component running as SYSTEM, illumio-ven-ctl [1]. The sources do not expand the acronym VEN, and they do not describe its overall purpose, so this article does not define it further [1].

Several terms are needed to follow the issue. LOCAL SERVICE is a built-in, low-privilege Windows account used by services that need only limited local rights (general background, not drawn from the pack). SYSTEM is the highest-privileged local account on a Windows host (general background). Access control lists (ACLs) are the rules that decide which accounts may read, write or execute a file or folder (general background). A trust boundary is the line between components that handle data with different levels of trust. Here, the boundary lies between a lower-privileged account that can write to the VEN folders and a SYSTEM-level component that acts on what it reads there [1].

The record places the trust boundary violation in the file system rather than in a network interface. The component trusts content that a lower-privileged principal is able to change [1].

Vulnerability description

The security property affected is the integrity of the privileged component's configuration. The lower-privileged LOCAL SERVICE account can write to folders that hold files the SYSTEM component trusts. This weakens the separation between a service account and the highest local account [1].

The flawed element is the permission set the VEN installer applies. The installer gives the built-in LOCAL SERVICE account broad rights over the product's data and install directories [1].

An attacker who already runs code as LOCAL SERVICE can use these rights to change the VEN configuration so that the SYSTEM-level illumio-ven-ctl component executes an injected command under the SYSTEM account [1]. The record therefore supports command execution at SYSTEM level as the documented outcome.

Conditions that must exist for the flaw to matter are the following. The host must run an affected VEN release for Windows [1]. An attacker must already execute code as LOCAL SERVICE on that host [1]. The attacker must be able to alter the configuration the SYSTEM component reads [1].

What the reviewed sources do not establish: whether the flaw is reachable from a remote position without a prior local foothold; whether any other platform is affected; and whether the flaw permits reading protected data, since the record describes the outcome as command execution and not data disclosure. The CVSS confidentiality impact rating of High is a vendor-supplied score and the pack does not explain how it was reached [1].

Root cause analysis

Confirmed: the weakness is classified as an incorrect permission assignment for a critical resource (CWE-732) [1]. The record states that the installer grants LOCAL SERVICE broad rights over the VEN data and installation folders, and that the SYSTEM-level component reads and trusts files in those folders [1].

Analyst assessment: the root cause is a design error in how the installer sets ACLs. It grants write-capable rights to a lower-privileged account on locations whose contents a higher-privileged process consumes as trusted input. Existing controls can fail here because the permission is set once at installation and nothing in the record shows that the trusted-input path verifies who wrote the files or whether they have changed [1]. This is inferred from the record's description and has not been confirmed by a source.

Not established by the reviewed sources: the exact installer logic and the list of affected folders; whether the permissions are inherited or set explicitly; whether the component checks signatures or integrity of its configuration files; and whether the -S1 releases change the ACLs, the component's validation logic, or both. The advisory content that would answer these questions is not in the pack [1].

Technical mechanics

The following numbered flow describes the mechanism as the record describes it. Steps marked Illustrative are not documented by a source.

  1. The VEN installer runs on a Windows host and sets permissions on the VEN data and installation directories. These permissions grant the LOCAL SERVICE account broad rights [1].
  2. The SYSTEM-privileged component illumio-ven-ctl reads configuration and state files from those directories during operation [1].
  3. The component treats the content of these files as trusted. The record does not describe a check that would detect unauthorized modification [1].
  4. Precondition, Illustrative: an attacker obtains code execution as LOCAL SERVICE through some other weakness. The record does not say how this initial access is obtained [1].
  5. The attacker, now acting as LOCAL SERVICE, modifies the VEN configuration because the ACLs allow it [1].
  6. When the SYSTEM component processes the altered configuration, it executes an injected command in the SYSTEM context [1].
  7. Controls that should have prevented the outcome, Analyst assessment: ACLs that restrict writes to administrative and SYSTEM principals only, and integrity validation of configuration that the SYSTEM component reads. Either control would break the chain at step 5 or step 6.

The record does not describe parsing or memory behaviour, so none is claimed here [1].

Attack surface and exploitation prerequisites

FactorAssessmentBasis
Access vectorLocal. Remote network reach is not indicatedS1, vector AV:L
Adjacent networkNot applicable under the vectorS1
Physical accessNot established by the sourcesS1
Authentication and privilegeRequires low privileges (PR:L). The record specifically requires code execution as LOCAL SERVICES1
User interactionNone required under the vector (UI:N)S1
ScopeUnchanged under the vector (S:U), which the record uses to describe a flaw that stays within the vulnerable component's authority scope in the scoring modelS1
Required configurationAn affected VEN release for Windows. Whether the vulnerable permissions are the shipped default or can be changed by the operator is not establishedS1
Attacker positionRunning code as LOCAL SERVICE on the hostS1
Environmental dependenciesThe SYSTEM-level component must read the affected files when it runs. The record does not state how often or under what triggersS1

Prerequisites marked as coming from the vector alone are the access vector, the scope and the user interaction factors. The requirement for LOCAL SERVICE code execution is stated in the record's description, not only in the vector [1]. Exploitability should not be inferred from the score alone. No proof of concept appears in the pack [1, 3].

Exploitation scenarios and attack lifecycle

Illustrative scenario: an attacker gains code execution as LOCAL SERVICE through an unrelated weakness in another service on a Windows host running an affected VEN release. The attacker then uses this flaw to change the VEN configuration and obtain SYSTEM-level command execution [1]. The record documents the second stage and the LOCAL SERVICE requirement. It does not document the first stage, so the initial-access path is not confirmed.

Defensive opportunities in this scenario. Preventive: restrict the write rights in the VEN directories and reduce the number of services that run as LOCAL SERVICE (Analyst assessment). Detective: monitor unexpected changes to VEN configuration and unexpected child processes of the SYSTEM-level component (Analyst assessment; the pack contains no event IDs or telemetry specifications for this). Containment: isolate the host and review its privileged activity once escalation is suspected.

No confirmed attack chain beyond the documented two-stage requirement is available in the reviewed sources [1].

Impact analysis

AreaTechnically documentedPlausible downstream consequence (Analyst assessment)
ConfidentialityVendor CVSS rates confidentiality impact High [1]. The record does not describe a specific data disclosureAccess to host data and credentials held by SYSTEM-level processes
IntegrityVendor CVSS rates integrity impact High. The record describes modification of VEN configuration [1]Tampering with the VEN's own behaviour on the host, including the policy or state it holds
AvailabilityVendor CVSS rates availability impact High [1]. The record does not describe a specific denial of serviceDisruption of the host or the VEN service if an injected command or configuration change disables it
Authentication and authorizationThe flaw crosses from a LOCAL SERVICE context to a SYSTEM context [1]Loss of separation between service accounts and the local administrative account
Privilege boundaryDocumented as local privilege escalation to SYSTEM [1]Full control of the affected host once SYSTEM is reached
Data and privacyNot established by the reviewed sourcesDepends on the data the host stores or processes
Business operationsNot established by the reviewed sourcesDepends on the role of the host and whether the VEN is needed for its operation
Regulatory or contractualNot established by the reviewed sourcesDepends on the organization's obligations for the affected systems

The table separates what the sources document from consequences that follow only by inference.

Affected products and versions

The vendor's CVE record gives the following affected ranges. Each range starts at the first listed version and ends before the -S1 release. Affected means the range includes the version and the fixed release is the -S1 version [1].

Product as listedAffected fromAffected beforeFixed versionSource and qualification
Illumio Core Ven26.2.1226.2.12-S126.2.12-S1S1, vendor CNA range
Illumio Core Ven25.2.4125.2.41-S125.2.41-S1S1, vendor CNA range
Illumio Core Ven25.2.4025.2.40-S125.2.40-S1S1, vendor CNA range
Illumio Core Ven25.2.3125.2.31-S125.2.31-S1S1, vendor CNA range
Illumio Core Ven25.2.2025.2.20-S125.2.20-S1S1, vendor CNA range
Illumio Core Ven25.2.1025.2.10-S125.2.10-S1S1, vendor CNA range
Illumio Core Ven24.2.4024.2.40-S124.2.40-S1S1, vendor CNA range
Illumio Core Ven24.2.3524.2.35-S124.2.35-S1S1, vendor CNA range
Illumio Core Ven24.2.3024.2.30-S124.2.30-S1S1, vendor CNA range
Illumio Core Ven24.2.2024.2.20-S124.2.20-S1S1, vendor CNA range
Illumio Core Ven24.2.1124.2.11-S124.2.11-S1S1, vendor CNA range
Illumio Core Ven24.2.1024.2.10-S124.2.10-S1S1, vendor CNA range
Illumio Core Ven23.2.3123.2.31-S123.2.31-S1S1, vendor CNA range
Illumio Core Ven23.2.31-LA23.2.31-LA-S123.2.31-LA-S1S1, vendor CNA range
Illumio Core Ven23.2.3023.2.30-S123.2.30-S1S1, vendor CNA range
Illumio Core Ven23.2.2423.2.24-S123.2.24-S1S1, vendor CNA range
Illumio Core Ven23.2.24-LA23.2.24-LA-S123.2.24-LA-S1S1, vendor CNA range
Illumio Core Ven23.2.2323.2.23-S123.2.23-S1S1, vendor CNA range
Illumio Core Ven23.2.2223.2.22-S123.2.22-S1S1, vendor CNA range
Illumio Core Ven23.2.22-LA23.2.22-LA-S123.2.22-LA-S1S1, vendor CNA range

Qualifications. The platform restriction to Windows comes from the record description, not from the range entries [1]. The record lists ranges per release line; it does not state that every intermediate build is included, so any build not matching a listed starting point is not classified here. Whether releases older than the earliest listed version are affected is not established by the reviewed sources. The vendor's advisory, which may clarify the range, is not in the pack [1]. No conflicting version ranges appear among the reviewed sources, because only one vendor-published range set is in the pack.

Exploitation and threat intelligence status

Confirmed exploitation in the wild: not established by the reviewed sources. Nothing in the pack reports a confirmed exploitation event [1, 2].

CISA KEV status: not listed as of 2026-11-12 [2]. The catalog check is a point-in-time result and does not show that the flaw has not been exploited [2].

EPSS: 0.0010 (0.10%), percentile 0.0092, dated 2026-11-10, for estimated exploitation activity over the next 30 days [3]. The FIRST source describes this as a statistical estimate and not as evidence of exploitation [3].

Public proof of concept: none is referenced in the pack [1]. Threat actors, campaigns and targeted sectors: not established by the reviewed sources.

Reliability of the evidence: the absence of exploitation evidence in this pack is not proof that exploitation has not occurred. The reviewed sources cover a short period after publication, and the pack contains no threat intelligence reporting on this CVE [1, 2, 3].

Indicators of compromise

No indicators of compromise are given in the reviewed sources. No file hashes, file names, domains, IP addresses, process names, command lines or event IDs are provided for this CVE [1, 2, 3]. No indicator is invented here.

Generic observation areas, not drawn from any source (Analyst assessment): unexpected modifications to files in the VEN data and installation directories, and unexpected child processes spawned by the SYSTEM-level component. Any indicator derived from these areas must be validated against a known-good baseline on the host before it is blocked or used for alerting, because indicators go stale and can produce false positives.

Detection and exposure assessment

Step 1, asset inventory: list every Windows host where the Illumio VEN is installed. The pack does not give the install path, the service name or the product's version command, so these must be taken from the vendor's installation documentation or from the existing asset inventory [1]. Prerequisite: an inventory tool or CMDB that records installed software on Windows hosts.

Step 2, version comparison: compare each installed version with the affected table in this article. A version inside an affected range is a version-based exposure, not proof that the flaw is exploitable on that host [1].

Step 3, permission check, read-only: on each host, display the ACLs of the VEN data and installation directories with the standard Windows tool icacls, using the path and no modifying switches. Expected result: the output lists the LOCAL SERVICE principal. A write-capable entry for LOCAL SERVICE indicates the condition the record describes [1]. Limitation: the exact directories are not listed in the pack, so the vendor documentation must confirm them first.

Step 4, authenticated vulnerability scanning: run an authenticated scan that reads installed software and file permissions. The pack does not name a scanner plugin or vendor check, so confirm coverage with the scanner vendor before relying on it.

Step 5, service review: list the services that run as LOCAL SERVICE on each host. Services that do not need that account are candidates for review. Limitation: a service running as LOCAL SERVICE is not evidence of exploitation.

Step 6, log and telemetry review: where file-system auditing is enabled, review changes to VEN directories. The pack gives no event IDs, so the audit policy and event categories must be selected by the team (Analyst assessment).

A version match, a permissive ACL, or a clean scan does not on its own establish that a host is safe or unsafe. The results should be correlated.

Immediate mitigation

Each measure below is an interim step. None is a vendor fix. The vendor has published the -S1 releases as the fixed versions, and the mitigations here follow from the component's documented behaviour, as described in the record [1].

  1. Restrict write access for LOCAL SERVICE on the VEN data and installation directories so that only administrative and SYSTEM principals keep write rights (derived from the record's description; not vendor-confirmed). Protects against: the configuration-modification step. Limitations: does not remove other paths to SYSTEM and does not fix the installer. Side effects: the VEN or its component may fail if it needs write access it does not have; test on a non-production host first. Verification: repeat the read-only icacls check and confirm the VEN service still starts and operates.
  2. Reduce the number of services that run as LOCAL SERVICE, disabling those that are not needed (Analyst assessment). Protects against: code execution in the first stage. Limitations: does not address the flaw itself. Side effects: the disabled service may be required by the host. Verification: list the services running as LOCAL SERVICE before and after the change.
  3. Restrict interactive and remote logon on VEN hosts to named administrators (Analyst assessment). Protects against: attackers without an administrative foothold. Limitations: does not block a foothold through a service. Side effects: administrative workflows may change. Verification: review local logon rights and remote logon policy on each host.
  4. Enable file-system auditing on VEN directories and forward those events to central logging (Analyst assessment). Protects against: undetected changes. Limitations: detects, does not prevent. Side effects: increased log volume. Verification: make a controlled, authorized change in a test environment and confirm the event reaches the central log.
  5. Prioritize patching of hosts that run an affected release, as described in the permanent remediation section.

Permanent remediation

Vendor-confirmed fix as listed in the CVE record: the fixed release for each affected release line is the -S1 version in the affected table [1]. A host on an affected release should be moved to the -S1 release of the same line. For example, a host on 25.2.41 should move to 25.2.41-S1 [1].

What is not confirmed by the pack: the detailed content of the fix, including whether the ACLs are corrected, whether the component adds validation, and whether reinstallation or a repair step is required. These details are expected in the vendor advisory, which is not in the pack [1].

Upgrade prerequisites and considerations. Back up the host or take a snapshot according to the organization's change process before the upgrade. Schedule a maintenance window. Define a rollback path. The reviewed sources do not state whether a reboot or service reload is required [1].

Configuration changes after updating: not established by the reviewed sources. Verify the ACLs after the upgrade with the read-only check described in the detection section. Do not assume the upgrade corrected them until that check confirms it.

Recommended hardening beyond the vendor fix (Analyst assessment): apply the restrictive ACL on the VEN directories and retain it after the upgrade if the vendor fix does not set it, after confirming that the VEN still runs.

Workarounds and compensating controls

The mitigations listed earlier are the available compensating controls. Their residual risk is significant. A LOCAL SERVICE compromise is still possible if the first-stage weakness remains, and the restrictive ACL depends on the component working correctly with the changed rights. These measures reduce exposure but are not equivalent to the vendor's fixed release, because they do not correct the installer behaviour the record describes [1].

No vendor-supported workaround is documented in the pack. Where the -S1 release cannot be deployed quickly, the compensating controls should remain in place until the fix is validated, and an exception should be recorded with an owner and an expiry date.

Validation and verification

Checklist for each host after the fix:

  1. Confirm the installed version matches the -S1 release for the line in the affected table. Use the product's own version output, which the pack does not name, so take the method from the vendor documentation [1].
  2. Re-run the read-only icacls check on the VEN data and installation directories and confirm that LOCAL SERVICE has no write rights, or that any remaining rights are documented and accepted (Analyst assessment).
  3. Confirm that the VEN service starts and that the SYSTEM-level component processes configuration without errors. Review the event log for failures after the change.
  4. Confirm that the compensating controls that are still needed remain in place, such as the service reduction and logon restrictions.
  5. Run an authenticated scan and confirm the host is no longer reported as affected by CVE-2026-114031. The scan's coverage of this CVE must be confirmed with the scanner vendor.
  6. Review file-system audit logs for unexpected changes in the period before and after the fix.
  7. Record the evidence, the owner, the date, and any exceptions in the change or vulnerability management system.

A single check does not show that the host is secure. The results of the version check, permission check, scan and log review should agree before the item is closed.

Incident response

Use the organization's incident response plan. Do not delete VEN files, logs or processes while investigating, because this could erase evidence.

Triage and scope: determine which hosts run an affected release and whether there is evidence of LOCAL SERVICE code execution or unexpected changes to VEN configuration. The pack provides no specific indicators, so this must rely on host and log evidence (Analyst assessment).

Containment: if escalation to SYSTEM is suspected, isolate the host from the network according to the plan, while preserving volatile data where the plan requires it.

Evidence preservation: copy the VEN configuration and state files and relevant logs to a protected location using read-only methods, and record hashes of the copies (Analyst assessment).

Investigation: review service and process history for the LOCAL SERVICE account and the SYSTEM-level component; review file-system audit logs for changes to VEN directories.

Credentials and secrets: if the evidence shows SYSTEM-level command execution, treat the host as fully compromised, and rotate credentials that were stored or used on the host, as the evidence warrants (Analyst assessment).

Eradication and recovery: apply the -S1 release, verify the ACLs, and rebuild the host where the investigation cannot rule out SYSTEM-level compromise.

Monitoring after recovery: keep the file-system auditing enabled for the VEN directories and review it for a defined period.

Notification and reporting: follow the organization's legal and contractual obligations. The pack contains no information about the affected data or regulatory duties, so these must be assessed by the organization.

Lessons learned: record how the first-stage LOCAL SERVICE access was obtained, if it is discovered, and whether the host inventory and patching process were fast enough.

Security hardening and prevention

Secure installer design (Analyst assessment, linked to CWE-732 [1]): set ACLs that grant write rights only to the principals that need them, and grant the SYSTEM-level component's inputs the minimum rights it needs. Review every permission rule the installer applies during code review and test it against a checklist.

Configuration integrity (Analyst assessment): where the SYSTEM-level component reads configuration, verify its integrity, for example through a signature or a protected location, before acting on it. The pack does not state whether the component does this, so the team should ask the vendor.

Regression testing: add an automated test that installs the product on a clean Windows image and asserts the ACL state of the VEN directories. Run it on every release.

Attack-surface reduction: reduce the services that run as LOCAL SERVICE and the number of local accounts that can execute code on VEN hosts (Analyst assessment).

Patch and vulnerability management: track the VEN release line of every Windows host in the inventory, and set a target window for applying vendor fixes.

Logging and monitoring: enable file-system auditing on directories that privileged components trust, and alert on changes (Analyst assessment).

The measures above are defence-in-depth recommendations and are not confirmed by the vendor.

Risk assessment

Technical severity: the vendor's CVSS 3.1 score is 7.8 HIGH [1]. This score is vendor-supplied and reflects the vector, not a measured exposure in the organization.

Exposure and asset criticality: depend on how many Windows hosts run affected releases and on the role of each host. The pack does not contain this information, so it must be supplied by the organization.

Exploit prerequisites and attacker opportunity: local access and LOCAL SERVICE code execution are required [1]. This reduces the opportunity for an external attacker who has no foothold on the host.

Evidence of exploitation: none confirmed in the pack; not listed in CISA KEV as of 2026-11-12; EPSS 0.0010 [2, 3].

Potential business impact: SYSTEM-level command execution on a host could affect its data, availability and trust relationships (Analyst assessment). The size of this impact depends on the host.

Existing controls and residual risk: the pack does not describe the organization's controls. Residual risk remains until the -S1 release is deployed and verified.

Recommended remediation priority (Analyst assessment with stated assumptions): assume the organization runs affected Windows VEN hosts and that some of them are reachable by users or services that could hold LOCAL SERVICE code execution. Under these assumptions, prioritize the interim permission restriction and the upgrade of hosts with the highest asset criticality first, with the upgrade of all affected hosts following on the normal change cycle. This is an organization-specific judgement and is not the CVSS score.

Conclusion

The core flaw is an incorrect permission assignment (CWE-732) that gives the LOCAL SERVICE account write-capable rights over folders that the SYSTEM-level illumio-ven-ctl component trusts [1]. Anyone who operates Windows hosts with affected Illumio VEN releases should act, with the system and security teams taking the lead. The most urgent interim step is to restrict LOCAL SERVICE write access to the VEN directories after confirming the directories and testing the change, since this is derived from the component's behaviour and not confirmed by the vendor [1]. The permanent fix is to move each affected host to the -S1 release of its release line [1]. The evidence needed to close the issue is a verified installed version on every affected host, a read-only ACL check showing no unintended write rights, a successful scan result, and a review of logs showing no unexplained changes to the VEN directories.

Remediation checklist

  1. Inventory every Windows host with the Illumio VEN installed and record each installed version; compare each with the affected table and treat any match as exposed [1].
  2. Confirm the VEN data and installation directories from vendor documentation, then run a read-only icacls check on each to see whether LOCAL SERVICE holds write rights [1].
  3. Remove LOCAL SERVICE write rights on those directories on a test host first, confirm the VEN service still starts and operates, then apply the same change to production; this is derived from component behaviour and not vendor-confirmed [1].
  4. Reduce the services that run as LOCAL SERVICE on VEN hosts, starting with any that do not need that account, and record the before and after list (Analyst assessment).
  5. Restrict interactive and remote logon on VEN hosts to named administrators and verify the policy with the local logon rights review on each host (Analyst assessment).
  6. Upgrade each affected host to the -S1 release of its own line, for example 25.2.41 to 25.2.41-S1, following the change process with a backup or snapshot and a rollback plan [1].
  7. After each upgrade, confirm the installed version and re-run the read-only ACL check; do not assume the fix changed the permissions until the check confirms it [1].
  8. Enable file-system auditing on the VEN directories and forward events to central logging, then test with an authorized change to confirm the event is recorded (Analyst assessment).
  9. Obtain the vendor advisory and confirm the fix content, reboot requirements and any post-upgrade configuration steps before closing the item [1].
  10. Run an authenticated scan after patching and confirm the host is no longer reported as affected; confirm scanner coverage of CVE-2026-114031 with the scanner vendor.
  11. Record evidence for each host, including owner, date, version, ACL result and exceptions, and keep compensating controls in place until the fixed version is verified.

Evidence gaps

  • The vendor advisory content is not in the pack; it is needed to confirm the fix details, whether ACLs change in the -S1 releases, reboot requirements and any post-upgrade configuration steps [1].
  • The exact installer logic, the list of affected directories and whether the permissions are inherited are not established; the advisory or vendor documentation would settle this [1].
  • Whether illumio-ven-ctl validates the integrity of the configuration files it reads is not established; vendor engineering documentation would settle this [1].
  • Whether releases older than the earliest listed version in each line, or platforms other than Windows, are affected is not established; the vendor's complete affected-range statement would settle this [1].
  • The record status is Received and the pack contains no NVD analysis or NVD-assigned CVSS score; a later NVD analysis would provide an independent score and CWE review [1].
  • No exploitation evidence, public proof of concept, threat actor attribution or indicators of compromise are in the pack; vendor or threat intelligence reporting would be needed [1, 2, 3].
  • The product's version command, the VEN service name and the install paths are not in the pack; the vendor documentation or the organization's inventory would settle these.
  • The expansion of the acronym VEN and the product's architecture and purpose are not given by the reviewed sources [1].

References

  1. CVE-2026-114031 record. NIST National Vulnerability Database (NVD), 2026-11-10. https://nvd.nist.gov/vuln/detail/CVE-2026-114031. Accessed 2026-11-12. CVE identity, record status and dates, vendor-supplied description of the flaw and trust boundary, CVSS 3.1 score and vector, scorer, CWE-732 mapping, vendor affected ranges and -S1 fixed versions, the Windows platform restriction, the LOCAL SERVICE requirement and the related vendor advisory refere
  2. Known Exploited Vulnerabilities Catalog. Cybersecurity and Infrastructure Security Agency (CISA), 2026-11-12. https://www.cisa.gov/known-exploited-vulnerabilities-catalog. Accessed 2026-11-12. Status of CVE-2026-114031 as not listed in the CISA KEV catalog as of 2026-11-12, and the caveat that this does not show absence of exploitation.
  3. EPSS score for CVE-2026-114031. FIRST, 2026-11-10. https://api.first.org/data/v1/epss?cve=CVE-2026-114031. Accessed 2026-11-12. FIRST EPSS estimate of 0.0010 (0.10%) with percentile 0.0092 dated 2026-11-10, and the statement that EPSS is a statistical estimate rather than evidence of exploitation.

Written with AI assistance from the 3 sources listed above, as of the research cut-off; each fact is cited to its source. Check the vendor's advisory before acting.

Summary

Incorrect permission assignment allows local privilege escalation to SYSTEM on affected releases of the Illumio VEN for Windows. Code execution as NT AUTHORITY\LOCAL SERVICE on the Windows host is required to exploit this vulnerability. The flaw exists within the VEN installer, which grants LOCAL SERVICE full access to the VEN data and installation folders, whose configuration and state files are read and trusted by the SYSTEM-privileged illumio-ven-ctl component. An attacker can leverage this vulnerability to modify the VEN configuration so that illumio-ven-ctl executes an injected command in the context of the SYSTEM account.

Description: NIST National Vulnerability Database (public domain)

Severity breakdown

High · 7.8 CVSS 3.1 base score from the CNA (illumio.com)

An attacker with a normal user account can exploit this with local access, without any user action.

Attack from
local access (a logged-in user, or a malicious file opened on the device)
Attack complexity
low (no special conditions)
Login needed
yes, a normal user account
User action needed
no
Scope
stays within the vulnerable component
Impact
high on confidentiality, integrity and availability

Vector CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Weakness

  • CWE-732: Incorrect Permission Assignment for Critical Resource

Affected and fixed versions

ProductAffected versionsFixed in
Illumio Core Ven≥ 26.2.12, < 26.2.12-S126.2.12-S1
≥ 25.2.41, < 25.2.41-S125.2.41-S1
≥ 25.2.40, < 25.2.40-S125.2.40-S1
≥ 25.2.31, < 25.2.31-S125.2.31-S1
≥ 25.2.20, < 25.2.20-S125.2.20-S1
≥ 25.2.10, < 25.2.10-S125.2.10-S1
≥ 24.2.40, < 24.2.40-S124.2.40-S1
≥ 24.2.35, < 24.2.35-S124.2.35-S1
≥ 24.2.30, < 24.2.30-S124.2.30-S1
≥ 24.2.20, < 24.2.20-S124.2.20-S1
≥ 24.2.11, < 24.2.11-S124.2.11-S1
≥ 24.2.10, < 24.2.10-S124.2.10-S1
≥ 23.2.31, < 23.2.31-S123.2.31-S1
≥ 23.2.31-LA, < 23.2.31-LA-S123.2.31-LA-S1
≥ 23.2.30, < 23.2.30-S123.2.30-S1
≥ 23.2.24, < 23.2.24-S123.2.24-S1
≥ 23.2.24-LA, < 23.2.24-LA-S123.2.24-LA-S1
≥ 23.2.23, < 23.2.23-S123.2.23-S1
≥ 23.2.22, < 23.2.22-S123.2.22-S1
≥ 23.2.22-LA, < 23.2.22-LA-S123.2.22-LA-S1

From the vendor's CVE record; confirm with the vendor advisory before relying on a version number.

References by type

Other references

Details from NVD (public domain).

Affected

  • Illumio Core Ven

Frequently asked questions

What is CVE-2026-114031?

CVE-2026-114031 is a permission-assignment weakness (CWE-732) in the Windows build of the Illumio VEN, which can let a local account that already runs code as LOCAL SERVICE raise its rights to SYSTEM. The only score in the pack is CVSS 3.1 7.8 HIGH with vector CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H, recorded by the vendor's security address as a Secondary scorer. Weakness type: Incorrect Permission Assignment for Critical Resource (CWE-732).

How severe is CVE-2026-114031?

CVE-2026-114031 has a CVSS 3.1 base score of 7.8 (high), from the CNA (illumio.com). An attacker with a normal user account can exploit this with local access, without any user action.

Is CVE-2026-114031 being exploited?

Not as far as is known: CVE-2026-114031 is not in CISA's Known Exploited Vulnerabilities catalog as of November 26, 2026. EPSS estimates a 0.1% chance that it is exploited in the next 30 days.

Which versions are affected by CVE-2026-114031?

Illumio Core Ven ≥ 26.2.12, < 26.2.12-S1 (fixed in 26.2.12-S1); Illumio Core Ven ≥ 25.2.41, < 25.2.41-S1 (fixed in 25.2.41-S1); Illumio Core Ven ≥ 25.2.40, < 25.2.40-S1 (fixed in 25.2.40-S1); Illumio Core Ven ≥ 25.2.31, < 25.2.31-S1 (fixed in 25.2.31-S1); and more, listed on this page.

How do I fix CVE-2026-114031?

Inventory every Windows host with the Illumio VEN installed and record each installed version; compare each with the affected table and treat any match as exposed. Confirm the VEN data and installation directories from vendor documentation, then run a read-only icacls check on each to see whether LOCAL SERVICE holds write rights. Remove LOCAL SERVICE write rights on those directories on a test host first, confirm the VEN service still starts and operates, then apply the same change to production; this is derived from component behaviour and not vendor-confirmed.

Timeline & sources

References

Related vulnerabilities & news