CVE-2026-10765 — Hitachi Energy RTU500 series CMU firmware
One of 4 Hitachi Energy RTU500 series CMU firmware vulnerabilities published together by NVD: our article covers all of them.
IoTVulnerabilitiesResearch article
Hitachi Energy RTU500 IEC 61850 Denial-of-Service Vulnerability
| CVE | CVE-2026-10765 |
|---|---|
| Vendor and product | Hitachi Energy RTU500 series CMU firmware |
| Published | November 26, 2026 10:05 UTC |
| Research cut-off | November 26, 2026 09:15 UTC |
| Sources reviewed | 3: NVD record (last modified 2026-11-24); CISA KEV catalog; FIRST EPSS (2026-11-25) |
Executive summary
CVE-2026-10765 affects Hitachi Energy RTU500 series CMU firmware in the separate ranges 13.5.1 to 13.5.4, 13.6.1 to 13.6.3, 13.7.1 to 13.7.8, and version 13.8.1 [1]. The flaw, categorized as a Use After Free condition [1], could allow an attacker with access to the IEC 61850 interface to trigger improper handling of asynchronous control operations, potentially causing a denial-of-service [1]. The reviewed sources do not indicate any known exploitation [2]. The CVSS 3.1 score is 5.9 MEDIUM, assigned by cybersecurity@hitachienergy.com [1].
Key points
- CVE-2026-10765 is a Use After Free condition in Hitachi Energy RTU500 series CMU firmware [1].
- The CVSS 3.1 score is 5.9 MEDIUM, assigned by cybersecurity@hitachienergy.com [1].
- The vulnerability could lead to a denial-of-service, software crash, or device reboot [1].
- CVE-2026-10765 is not listed in the CISA Known Exploited Vulnerabilities Catalog [2].
- The EPSS score estimates a 0.40% probability of exploitation within the next 30 days [3].
Vulnerability identification
| Field | Value |
|---|---|
| CVE ID | CVE-2026-10765 |
| Vendor | Hitachi Energy |
| Product | RTU500 series CMU firmware |
| CWE | CWE-416 (Use After Free) |
| CVSS 4.0 | 8.2 HIGH, scored by cybersecurity@hitachienergy.com [1] |
| CVSS 3.1 | 5.9 MEDIUM, scored by cybersecurity@hitachienergy.com [1] |
| Published | 2026-11-24 |
| Last Modified | 2026-11-24 |
| Record Status | Awaiting Analysis |
Vulnerability description
A denial-of-service flaw exists in the IEC 61850 MMS server implementation of the RTU500. An attacker with access to the IEC 61850 interface may be able to cause the system to mishandle asynchronous control operations that involve specific response and timing requirements. This could lead to access of invalid memory locations, resulting in a software crash, disruption of IEC 61850 communication, or a device reboot [1].
Attack surface and exploitation prerequisites
has high attack complexity (AC:H) [1] The attacker must have access to the IEC 61850 interface to exploit this flaw [1].
Impact analysis
The CVSS 3.1 vector indicates no impact on confidentiality (C:N) or integrity (I:N), but a high impact on availability (A:H). The vulnerability could result in a crash, loss of IEC 61850 communication, or a reboot of the device [1].
Affected products and versions
| Affected Product | Affected Version | Fixed Version |
|---|---|---|
| Hitachi Energy RTU500 series CMU firmware | ≥ 13.5.1, ≤ 13.5.4 | not listed |
| Hitachi Energy RTU500 series CMU firmware | ≥ 13.6.1, ≤ 13.6.3 | not listed |
| Hitachi Energy RTU500 series CMU firmware | ≥ 13.7.1, ≤ 13.7.8 | not listed |
| Hitachi Energy RTU500 series CMU firmware | 13.8.1 | not listed |
Exploitation and threat intelligence status
CVE-2026-10765 is not listed in the CISA Known Exploited Vulnerabilities Catalog as of 2026-11-26 [2]. The EPSS score suggests a 0.40% probability of exploitation within the next 30 days [3].
Detection and exposure assessment
Organizations should verify if they are running any of the affected versions of Hitachi Energy RTU500 series CMU firmware [1]. No specific detection methods are provided by the sources.
Remediation
The sources do not specify a fixed version for this CVE. Organizations should monitor for updates from the vendor regarding a patch or mitigation.
Remediation checklist
- Verify if the system is running any of the affected versions of Hitachi Energy RTU500 series CMU firmware [1].
- Monitor for updates from the vendor regarding a fixed version.
- Implement network access controls to prevent unauthorized access to the IEC 61850 interface.
Evidence gaps
- The sources do not describe the technical background of the product.
- The sources do not explain the root cause of the vulnerability beyond the CWE.
- The sources do not describe how the flaw works in technical mechanics.
- The sources do not describe any exploitation scenarios or attack lifecycle.
- The sources do not provide indicators of compromise.
- The sources do not mention any workarounds or compensating controls.
References
- CVE-2026-10765 record. NIST National Vulnerability Database (NVD), 2026-11-24. https://nvd.nist.gov/vuln/detail/CVE-2026-10765. Accessed 2026-11-26.
- Known Exploited Vulnerabilities Catalog. Cybersecurity and Infrastructure Security Agency (CISA), 2026-11-26. https://www.cisa.gov/known-exploited-vulnerabilities-catalog. Accessed 2026-11-26.
- EPSS score for CVE-2026-10765. FIRST, 2026-11-25. https://api.first.org/data/v1/epss?cve=CVE-2026-10765. Accessed 2026-11-26.
Summary
RTU500 contains a denial-of-service vulnerability in its IEC 61850 MMS server implementation. A malicious user with access to the IEC 61850 interface can trigger improper handling of asynchronous control operations involving special response and timing criteria. This may result in access to invalid memory structures, leading to a software exception, loss of IEC 61850 communications, or device reboot.
Severity breakdown
High · 8.2
An attacker without an account can exploit this over the network, without any user action, but only under specific conditions.
- Attack from
- the network (remotely)
- Attack complexity
- high (only works under specific conditions)
- Special conditions
- none
- Login needed
- no
- User action needed
- no
- Impact
- high on availability, none on confidentiality and integrity
- Impact on other systems
- none
Weakness
- CWE-416: Use After Free
Affected and fixed versions
| Product | Affected versions | Fixed in |
|---|---|---|
| Hitachi Energy RTU500 series CMU firmware | ≥ 13.5.1, ≤ 13.5.4 | — |
| ≥ 13.6.1, ≤ 13.6.3 | — | |
| ≥ 13.7.1, ≤ 13.7.8 | — | |
| 13.8.1 | — |
References by type
Other references
Affected
- Hitachi Energy RTU500 series CMU firmware
Frequently asked questions
What is CVE-2026-10765?
CVE-2026-10765 affects Hitachi Energy RTU500 series CMU firmware in the separate ranges 13.5.1 to 13.5.4, 13.6.1 to 13.6.3, 13.7.1 to 13.7.8, and version 13.8.1. The flaw, categorized as a Use After Free condition, could allow an attacker with access to the IEC 61850 interface to trigger improper handling of asynchronous control operations, potentially causing a denial-of-service. Weakness type: Use After Free (CWE-416).
How severe is CVE-2026-10765?
CVE-2026-10765 has a CVSS 4.0 base score of 8.2 (high), from the CNA (hitachienergy.com). An attacker without an account can exploit this over the network, without any user action, but only under specific conditions.
Is CVE-2026-10765 being exploited?
Not as far as is known: CVE-2026-10765 is not in CISA's Known Exploited Vulnerabilities catalog as of November 26, 2026. EPSS estimates a 0.4% chance that it is exploited in the next 30 days.
Which versions are affected by CVE-2026-10765?
Hitachi Energy RTU500 series CMU firmware ≥ 13.5.1, ≤ 13.5.4; Hitachi Energy RTU500 series CMU firmware ≥ 13.6.1, ≤ 13.6.3; Hitachi Energy RTU500 series CMU firmware ≥ 13.7.1, ≤ 13.7.8; Hitachi Energy RTU500 series CMU firmware 13.8.1.
How do I fix CVE-2026-10765?
Verify if the system is running any of the affected versions of Hitachi Energy RTU500 series CMU firmware. Monitor for updates from the vendor regarding a fixed version. Implement network access controls to prevent unauthorized access to the IEC 61850 interface.